Research Theme · 03

Retrofitting of
Buildings

Buckling-restrained braces for corroded, low-ductility RC frames: how much strength they give back, what they ask of the joints, and how to size them from a measured level of corrosion.

Based on journal paper Journal of Structural Design and Construction Practice and a paper at the 14th Structural Engineering Convention, 2024.

BRB ψ — rebar mass loss
fig. 3.0The 50-year corroded frame with buckling-restrained braces.
Sheet 1Context & motivation

Strengthening an ageing frame

In the corrosion study, 50 years of coastal exposure took more than half of the frame's lateral strength. Demolishing and rebuilding such buildings is rarely realistic at scale, retrofitting is. Buckling-restrained braces (BRBs) are a strong candidate, but they had never been studied on corrosion-damaged RC frames.

fig. 3.1The service-life story behind this theme. The as-built, 50-year and retrofitted levels come from the pushover analyses. (schematic)
Inside a buckling-restrained brace steel core yields in tension and compression casing and mortar stop it buckling unbonding layer lets the core slide freely Why it helps axial deformation axial force BRB: full, stable loops ordinary brace buckles in compression
fig. 3.2A buckling-restrained brace yields in both directions without buckling, so it keeps absorbing energy cycle after cycle (schematic).

What this study adds

Local responses → damage states

A way to map monitored local responses from columns, joints, braces to global responses for deteriorated, braced frames.

How strong should the braces be?

The first detailed look at how the chosen brace strength changes the seismic fragility of a corroded frame.

Fragility from two measurements

Generic, condition-dependent functions that give fragility straight from the corrosion and retrofit levels.

Sheet 2Methodology

Designing braces for a corroded frame

Start from the deteriorated frame of the corrosion study, add braces to its middle bay, and ask two questions: how much do they help and how does that answer change with the level of corrosion and the strength of the braces?

As built
baseline frame
50 years
deteriorated by corrosion
50 years + BRB
braces in the middle bay
fig. 3.3The three frames compared throughout.
01

Start from the aged frame

The 50-year frame from the corrosion study: non-uniform pitting and joint deterioration.

02

Size the braces

Brace strength set by a coefficient α; the baseline design is α = 1.

03

Model in OpenSees

A BRB device (truss, steelBRB material) in series with an elastic brace.

04

Analysis

Pushover for capacity, time-history for demand, with joint responses checked.

05

Generalise

Repeat across corrosion and retrofit levels, then fit fragility functions to both.

289 BRB device elastic brace
  • BRB device - truss element with the steelBRB material, connected at the beam–column joints
  • Elastic brace - elastic beam-column element on the diagonal
  • The two act in series, so the device takes the inelastic action

The frame, corrosion model and damage-state definitions are those of the corrosion study; only the braces are new.

fig. 3.4How a brace is implimented in the model.
Sheet 3Outcomes

Strength restored, with a catch at the joints

As built 50 years 50 years + BRB (α = 1)
Schematic capacity curves: braces nearly double the peak base shear of the corroded frame, bringing it close to the as-built level. Maximum inter-storey drift Base shear
fig. 3.5Capacity curves from pushover analysis, drawn schematically with the peak ratios from the study.

Nearly double the strength

With braces at α = 1 the corroded frame's peak base shear rises by almost 90%, close to where it stood when new.

Try it: corrosion level × retrofit level

Corrosion can be measured on site with destructive and non-destructive testing. The condition-dependent fragility functions turn that measurement and a candidate brace strength into the capacity of every damage state, no new analysis needed. Drag the point on the map, or use the sliders.

Design mapModerate damage · median Sa,avg
47%
1.00
All four damage statestap one to map it
As built Corroded Corroded + braces
Extra joint demand from the braces within limit

fig. 3.7Each damage state's median capacity is a plane in ψ and α, so its contours are straight lines; a stronger green wash means a stronger frame. The blue line marks where the corroded, braced frame gets back to its as-built capacity, and past α ≈ 2 the joints become the limit. Regression fits from the study shown to illustrate the framework for this frame (Not a design tool, The joint gauge is schematic).
A beam–column joint with a brace framing into it: the brace force adds to the joint's demand and increases its rotation. brace force more joint rotation
fig. 3.8A new load path through the joint (schematic).

The joints become the new weak spot

Braces add a load path, and the extra axial force they carry raises the demand on the beam–column joints. Column drift falls after retrofit, but joint rotations grow with α and become critical beyond a case-study specific limit.

For the layout studied here, rotations at α = 1 stay below the limit. Stronger or different brace layouts may not. Then the joints need local strengthening too, or premature joint failure can stop the frame from reaching its intended capacity.

Sheet 4Open for collaboration

Questions I'd like to work on with others

Retrofit research only matters if it reaches real buildings. These are the steps between this study and that each one better done with partners.

Braces plus joint strengthening

Combined schemes implimenting braces with jacketing or FRP at the joints, so the braces can deliver their full capacity without a premature joint failure.

Good fit for: retrofit designers, FRP and steel-jacketing specialists.

Testing the retrofit

Sub-assemblage, shake-table or hybrid tests on corroded RC frames with braces would validate the models and the joint limits that govern them.

Good fit for: labs with BRB fabrication and large-scale testing.

When to retrofit

Retrofit at 20 years of exposure, or 40? Coupling inspection data on ψ with life-cycle cost could tell owners when a retrofit pays off.

Good fit for: asset managers, infrastructure economists.

Other retrofits, same yardstick

FRP wraps, RC or steel jacketing and base isolation could be assessed with the same condition-dependent framework, putting the options on an equal footing.

Good fit for: modelling groups and retrofit practitioners.

Working on something related? I'd be glad to hear from you.

PapersFrom this theme
Under review
Buckling-restrained braces for seismic performance enhancement of corroded low-ductility RC building frames
Journal of Structural Design and Construction Practice
Conference · 2024
Seismic performance enhancement of corroded RC frames using buckling restrained braces
14th Structural Engineering Convention (SEC-2024), NIT Tiruchirappalli